Line to Load.
Althea Power is a self-perform electrical contractor. We build the power systems that energize critical infrastructure, from the point of interconnection to the load: substations, transmission and gen-ties, medium-voltage distribution, battery energy storage, utility-scale generation, and power for data centers and industrial facilities.
Every voltage. Every phase.
Althea Power is a specialty electrical contractor working across the full power delivery chain â from renewable generation and high-voltage transmission, through substations and medium-voltage distribution, to the commercial and mission-critical facilities at the end of the line.
That range is deliberate. The same crews, testing discipline, and project controls that energize a 230 kV substation carry into a campus MV loop or a commercial service entrance. It lets us serve utilities, IPPs, renewable developers, EPCs, general contractors, and building owners from one organization, and it lets clients keep a single contractor across scopes that would otherwise be split.
Our work is self-performed by licensed journeymen and qualified electrical workers, with in-house project management, estimating, and commissioning support, under a documented safety program built around OSHA 1910.269, NFPA 70E, and client site requirements.
- 480 V to 500 kV Self-perform range
- 29.43 GWdc Combined team experience
- 35 Substations, up to 500 kV
- 246 Projects built by our team
One contractor, the whole way down the line.
Power is generated, carried, stepped down, distributed and delivered. Althea Power self-performs the electrical work at every one of those stages, so the schedule-critical path stays with one crew and one set of controls.
-
DC to 35 kV
Generate
Utility-scale solar, wind and battery storage. DC collection through the point of interconnection.
-
Up to 230 kV
Transmit
Overhead and underground transmission. New lines, rebuilds, relocations and interconnections.
-
Up to 500 kV
Transform
Turnkey distribution and transmission substations, including work in energized yards.
-
5â35 kV
Distribute
Campus, industrial and site distribution. Underground and overhead, tested through energization.
-
480 V
Deliver
Mission-critical and commercial facilities, from the service entrance to the white space.
What we build
We self-perform electrical work from 480 V to 500 kV, from the point of interconnection to the load.
-

Renewable Energy
Electrical installation for solar, wind, and hybrid generation, wired and tested to protect your energy model.
View scope -

Site Electrical
AC/DC systems, grounding, and fiber installed and verified before they move forward.
View scope -

Medium Voltage Collection
5 to 34.5 kV collection systems trenched, terminated, and tested for the life of the plant.
View scope -

Substations
Collector and interconnection substations built, tested, and energized with the utility.
View scope -

Transmission Lines
Gen-tie and transmission lines delivering power to the point of interconnection.
View scope -

Battery Energy Storage
Safe, code-compliant BESS facilities commissioned and ready to dispatch.
View scope -

SCADA and Controls
Plant controls and communications that give owners and grid operators real-time visibility.
View scope
Markets
The same crews and controls across scopes that would otherwise be split.
-
Substations
Turnkey distribution and transmission substations, new build and expansion.
-
Transmission
Overhead and underground HV lines and gen-ties to the point of interconnection, up to 230 kV.
-
Mission critical
Power distribution for data centers and industrial facilities.
-
Renewable Energy & Storage
Utility-scale solar PV, wind, and battery energy storage.
-
Medium Voltage Distribution
5 kVâ35 kV systems, underground and overhead.
How the work gets done.
- Self-performed
- Licensed journeymen and qualified electrical workers on our own payroll. The scopes that decide the schedule are not subcontracted.
- In-house controls
- Project management, estimating and commissioning support from the same organization that fields the crews.
- Documented safety
- A written program built around OSHA 1910.269, NFPA 70E and each client's site requirements.
- Outage discipline
- Switching coordination, clearance management and compressed-window execution, planned early and held to daily.
Tell us about the project.
Send drawings, a one-line, or a rough scope. We will come back with questions and a schedule.
Request a quote