Critical facility maintenance performed to concurrent-maintainability standards, with the documentation and change control that operators require. We work in occupied, energized environments where the maintenance window is the constraint and an unplanned trip is the failure condition.

Concurrent maintainability. Change control. Zero unplanned trips.

  • Electrical Distribution
  • UPS & Battery Systems
  • Standby Generation
  • Predictive & Condition-Based
  • Program & Compliance
  • Staffing Models

Systems and what we do to them

Electrical Distribution

  • Preventive maintenance on medium- and low-voltage switchgear, breakers, and switchboards
  • Transformer inspection, testing, and oil analysis (dissolved gas, dielectric strength, moisture)
  • Busway inspection, torque verification, and thermographic survey
  • Automatic transfer switch inspection, testing, and timing verification
  • Protective relay testing, calibration, and settings verification

UPS & Battery Systems

  • UPS preventive maintenance, capacitor and fan life-cycle replacement
  • Battery testing and monitoring to IEEE 1188 (VRLA) and IEEE 450 (flooded)
  • Impedance and capacity testing, cell replacement, string commissioning
  • Lithium-ion BESS maintenance and BMS support
  • Battery room ventilation, spill containment, and safety compliance

Standby Generation

  • Generator preventive maintenance and manufacturer-interval service
  • Load bank testing — resistive and reactive, unit and system level
  • Paralleling switchgear and controls testing
  • Fuel system electrical, transfer pump controls, and fuel quality coordination
  • Black start and full facility pull-the-plug testing

Predictive & Condition-Based

  • Infrared thermography surveys with corrective work orders
  • Partial discharge testing and online monitoring
  • Power quality monitoring, harmonic analysis, and mitigation
  • Ultrasonic inspection and circuit breaker timing analysis
  • Trending and asset condition reporting against maintenance history

Program & Compliance

  • MOP, SOP, and EOP development, review, and field execution
  • NFPA 70B program development and maintenance interval scheduling
  • Arc flash studies, coordination studies, and label management
  • Single-line drawing maintenance and as-built reconciliation
  • Capacity and stranded-power assessment for expansion planning

Staffing Models

  • Scheduled preventive maintenance contracts, annual or multi-year
  • Embedded on-site technicians and critical facility electricians
  • 24/7 emergency response with defined response-time commitments
  • Project support for live expansions, tie-ins, and equipment replacement